Send Message
Home ProductsMV Voltage Transformer

IEC Bushing MV Voltage Transformer Proof Wound Safety And Isolating Energy

IEC Bushing MV Voltage Transformer Proof Wound Safety And Isolating Energy

  • IEC Bushing MV Voltage Transformer Proof Wound Safety And Isolating Energy
  • IEC Bushing MV Voltage Transformer Proof Wound Safety And Isolating Energy
  • IEC Bushing MV Voltage Transformer Proof Wound Safety And Isolating Energy
  • IEC Bushing MV Voltage Transformer Proof Wound Safety And Isolating Energy
  • IEC Bushing MV Voltage Transformer Proof Wound Safety And Isolating Energy
IEC Bushing MV Voltage Transformer Proof Wound Safety And Isolating Energy
Product Details:
Place of Origin: Shenzhen
Brand Name: Chuangyin
Certification: Kema,CE,SGS,TUV
Model Number: JDZX11-12/24/36PC
Payment & Shipping Terms:
Minimum Order Quantity: 1set
Price: negotiable
Packaging Details: Carton packing for one sets, one set including three piece with Components
Delivery Time: Within 7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 36,000,00pcs per year
Contact Now
Detailed Product Description
Construction: Insulation Structure Termal Limit Output: 300VA
Um: Up To 36KV Installation Site: Indoor
Rated Insulation Level: 24/50/125KV Type: Single-Phase
Standard: IEC Size: Electronic
High Light:

medium voltage transformer

,

medium voltage potential transformer

12/24/36kV Medium Voltage Transformer IEC Bushing Metallic Coating Touch Proof Wound Safety And Isolating Energy


1. Product Introduction:
 

Voltage transformer adopts fully enclosed casting insulation structure, which encloses the primary and secondary winding and the toroldal core In the epoxy resin casting body to Improve the filterability and moisture resistance. The product plug part Is designed to conform to the B type Inner cone (EN 50181). The overall structure is designed to be fully shielded surface. It is used indoor for measuring voltage, electric energy and protective relaying In single-phase or three-phase AC circuit with the frequency 50Hz or
60Hz and highest voltage for equipment 36kV.

 

Main technical parameter

1. Installation site: Indoor
2. Rated frequency: 50/60Hz
3. Load power factor: cos'=0.8 (lagging)
4. Technical standard accords with: I E C 60044-2
                                                         IEC 61869-183

 

Item Specification Unit Data
1 Um kV Up to 36
2 Rated Insulation Level kV Up to 36/70/170
3 Rated Primary Voltage V

33000/√3

22000/√3

11000/√3

4 Rated Secondary Voltage V 110/√3 or 110/√3
 

 

Type

Rated primary

voltage (kV)

Rated secondary voltage (kV) Accuracy classes combination

Rated output

(VA)

Thermal limiting current

(VA)

Rated insulation level(kV)
JDZX11-12/24/36PC

11/√3

22/√3

33/√3

0.11//√3 0.2 20 300

 

24/50/125

0.5 50
1 80
0.11/√3/0.11/3
 
0.2/6P(3P)   150
25/50
 
0.5/6P(3P) 50/50

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

 

 

Outline drawing

 

 
IEC Bushing MV Voltage Transformer Proof Wound Safety And Isolating Energy 0
IEC Bushing MV Voltage Transformer Proof Wound Safety And Isolating Energy 1
 
 
 
 
 
 
 

Contact Details
Shenzhen Chuangyin Co., Ltd.

Contact Person: Mr. Dieky Lin

Tel: +86 138 2379 0397

Fax: 86-0755-8600-0614

Send your inquiry directly to us (0 / 3000)

Other Products