Home ProductsMV Voltage Transformer

12kV outdoor MV PT epoxy resin single phase with silicone rubber 50/60Hz.

Good quality LV Current Transformer for sales
Good quality LV Current Transformer for sales
I'm Online Chat Now

12kV outdoor MV PT epoxy resin single phase with silicone rubber 50/60Hz.

China 12kV outdoor MV PT epoxy resin single phase with silicone rubber 50/60Hz. supplier
12kV outdoor MV PT epoxy resin single phase with silicone rubber 50/60Hz. supplier 12kV outdoor MV PT epoxy resin single phase with silicone rubber 50/60Hz. supplier

Large Image :  12kV outdoor MV PT epoxy resin single phase with silicone rubber 50/60Hz.

Product Details:

Place of Origin: China
Brand Name: Shenzhen Chuangyin Co., Lt
Certification: KEMA/type test report
Model Number: JDZW1-12R

Payment & Shipping Terms:

Minimum Order Quantity: 1pc
Price: Negetiable
Packaging Details: Plywood
Delivery Time: 8days
Payment Terms: L/C, T/T
Supply Ability: 36,000.00pcs per year
Contact Now
Detailed Product Description
Insulation Type: Dry /Silicone Composite Insulation Voltage: 12kV
Application: Outdoor Properties: Single Fase
Applied Standard: IEC 61869-1 &3 (IEC 60044-2) Rated Insulation Level: 12/28/75kV
Color: Red

Chuangyin Voltage Transformer-JDZW1-12R

 

Description:

 

This product is fully enclosed outdoor single-phase voltage transformer, epoxy resin and silicone rubber composite insulation support type. The outer sheath and sheds are made of high temperature vulcanized silicone rubber, good hydrophobicity, and highly improved the contamination flashover voltage. It has anti-aging property and with tracking resistance.

 

VT has inserted MV fuse in the primary terminal, with protective rubber cap for animal protection and sealing function. The transformer is suitable for rated frequency of 50/60Hz, the highest equipment voltage 12kV system. Mainly for measuring, energy metering, protection and auxiliary power supply, etc.

 

Basic technical data:

 

1. Installation: Outdoor
2. Insulation type: Dry, Silicone composite insulation
3. Highest voltage for equipment Um (r.m.s.) 12kV
4. Rated power-frequency withstand voltage (r.m.s.): 28kV
5. Rated lightning impulse withstand voltage (peak): 75kV
6. Rated frequency: 50Hz / 60Hz
7. Applied standard: IEC 61869-1 &3 (IEC 60044-2)

 

Specification:

 

Rated Primary Voltage

(kV)

Rated Secondary Voltage

(V)

Accuracy classes combination Rated Burden (VA) Thermal limiting Output (VA)

Rated Insulation Level

(kV)

10

11

100

110

115

120

220

240

0.2 15 500 12/28/75
0.5 50
0.5/3 30/300

 

 

 

 

 

 

 

 

 

 

 