Send Message
Home ProductsMV Current Transformer

24kv Indoor Measuring MV Current Transformer Epoxy Resin 50/60hz

24kv Indoor Measuring MV Current Transformer Epoxy Resin 50/60hz

  • 24kv Indoor Measuring MV Current Transformer Epoxy Resin 50/60hz
24kv Indoor Measuring MV Current Transformer Epoxy Resin 50/60hz
Product Details:
Place of Origin: Shenzhen
Brand Name: Chuangyin
Certification: Kema,CE,SGS,TUV
Model Number: LZZBJ10-24
Payment & Shipping Terms:
Minimum Order Quantity: 1set
Packaging Details: Plywood
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 36,000,00pcs per year
Contact Now
Detailed Product Description
Rated Insulation Level: 24/50/125 Kv Installation Site: Indoor
Type: Epoxy Resin Dry Type Material: Cast
Ratio: 15-1500/5 Ustage: Measuring And Protection
High Light:

medium voltage current transformer

,

single phase current transformer

 

 
24kv Indoor Single-Phrase Current Transformer Epoxy Resin for Measuring
 
 
 
1.Product Introduction:

 

LZZBJ10-17.5/24 current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omnidirectional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective relaying in the electrical system with the rated frequency 50- 60Hz and highest voltage for equipment 24kV

 

2. Technical Data:



Main technical parameter
1. Rated insulation voltage: 24/50/125kV etc.
2. Rated frequency: 50/60hz
3. Installation Site: Indoor
4. Standards: IEC60044-1(IEC61869-1&2) 

 

 
3. Specification:
 

Two Secondary Single Ratio

Rated

transformation ratio(A)

 

Accuary classes combination

Rated output(VA)

 

 

(ALF)

 

(FS)

Short-time thermal current Ith(kA/S) Rated dynamic current Idyn(kA)

 

Measuring

 

Protective

0.2(S) 0.5 10P

15/5

……

200/5

0.2(S)/0.2(S)

0.2(S)/0.5

0.5/0.5

0.2(S)/10P

0.5/10P

 

10 15

 

 

 

 

10

 

 

15

 

 

10

 

5

(10)

100I1n 250I1n
300/5 25 63
400/5 31.5 80
500/5 40 100
600/5 40 100
800/5 63 130
1000/5 63 130
1500/5 80 160

 

Two Secondary Double Ratio

Rated

transformation ratio(A)

 

Accuary classes combination

 

Rated output(VA)

 

 

 

(ALF)

 

(FS)

Short-time thermal current Ith(kA/S) Rated dynamic current Idyn(kA)
Measuring

 

Protective

0.2(S) 0.5 10P

15-30/5

20-40/5

……

200-400/5

0.2(S)/0.2(S)

0.2(S)/0.5

0.5/0.5

0.2(S)/10P

0.5/10P

 

10 15

 

 

 

10

 

15

 

 

10

 

5

(10)

75I1n 187.5I1n
300-600/5 31.5 80
500-1000/5 40 100
600-1200/5 50 130
750-1500/5 80 160
 
 
4. Outline Drawing:
 
 
24kv Indoor Measuring MV Current Transformer Epoxy Resin 50/60hz 0
 
 
 
 
5.Photos:
 
 
 
24kv Indoor Measuring MV Current Transformer Epoxy Resin 50/60hz 1
 
24kv Indoor Measuring MV Current Transformer Epoxy Resin 50/60hz 2