Home ProductsSplit Core Current Transformer

Clamp On Split Core Current Transformer Open Distributed Measurement Systems

Clamp On Split Core Current Transformer Open Distributed Measurement Systems

    • Clamp On Split Core Current Transformer Open Distributed Measurement Systems
  • Clamp On Split Core Current Transformer Open Distributed Measurement Systems

    Product Details:

    Place of Origin: ShenZhen
    Brand Name: Chuangyin
    Certification: Test Report
    Model Number: CY-QCT02-15

    Payment & Shipping Terms:

    Minimum Order Quantity: 1set
    Price: negotiable
    Packaging Details: Carton packing for one sets, one set including three piece with Components
    Delivery Time: Within 7 days
    Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability: 36,000,00pcs per year
    Contact Now
    Detailed Product Description
    Type: Split Core Current Transformer Feature: Maximum Measuring Current Up To 130A
    Ampere: 5A/100A Application: Measure Together With Other Kinds Of Instruments
    Operating Temperature: 0 To 500C (32-1220F) Operating Humidity: 580%RH
    High Light:

    split core current sensor

    ,

    split core current transducer

     

    100-3000A 50/60Hz Clamp-on Current Transformer Current Transformer / Open type CY-QCT01


    1.Product Introduction:

     


    The "QCT02-15 Clamp-on Current Transformer" is designed for easy installed in tight spaces and without the need for dismantling the primary busbar or cables. The sensing head uses sliding push-fit clamp structure, safety isolation to avoid the user to contact with charged objects directly. It complies with CE standards and meets 300V CAT III safety class.

     

    Feature:

     

    1. Flexible and light weights, exquisite appearance
    2. Easy &quick installation in tight spaces
    3. Excellent linearity
    4. Maximum measuring current up to 130A

     

    Application:

    1. Power quality monitoring
    2. CT secondary current detection
    3. Smart logger
    4. Distributed measurement systems

     

    General Data:

     

    1. Operating temperature & humidity: 0 to 500C(32-1220F),580%RH(No condensate)
    2. Storage temperature & humidity: -10 to 600C(14-1400F), 580%RH(No condensate)
    3. Operating environment: Indoor, altitude up to 2000 meters
    4. Standards Safety: IEC61010-1:2001,300V CAT III

     

    Dimension:

     

    Clamp On Split Core Current Transformer Open Distributed Measurement Systems 0

     

    Clamp On Split Core Current Transformer Open Distributed Measurement Systems 1

    Contact Details
    Shenzhen Chuangyin Co., Ltd.

    Contact Person: Isabel

    Send your inquiry directly to us (0 / 3000)

    Other Products