Send Message
Home ProductsMV Voltage Transformer

JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage Transformer

JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage Transformer

  • JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage Transformer
  • JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage Transformer
  • JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage Transformer
  • JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage Transformer
JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage Transformer
Product Details:
Place of Origin: Shenzhen
Brand Name: Chuangyin
Certification: Kema,CE,SGS,TUV
Model Number: JDZX16-12R
Payment & Shipping Terms:
Minimum Order Quantity: 1set
Price: negotiable
Packaging Details: Plywood
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 36,000,00pcs per year
Contact Now
Detailed Product Description
Rated Insulation Level: 12 KV Ustage: Switchgear
Type: With Fuse Accuracy: 0.2;0.5;1;0.2/6P;0.5/6P;0.2/0.5/6P;0.5/0.5/6P
Material: Epoxy Resin Frequency: 50/60hz
High Light:

medium voltage transformer

,

medium voltage potential transformer

JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage Transformer


 
1.Product Introduction:
 

Epoxy resin casting and full enclosed construction, is used indoor for measuring voltage, electric energy and protective relaying In single-phase or three-phase AC circuit with the frequency 50Hz or 6OHz and highest voltage for equipment 12kV.
The product has the feature of high reliability, low magnetism of core, large creepage distance of external insulation andmaintenance free etc.
The primary cone accords with IEEE 386-2006 figure 7.
 
 
2. Technical Data:

Main technical parameter
1. Rated insulation voltage: 16kV etc.
2. Rated frequency: 50/60hz
3. Installation Site: Indoor
4. Standards: IEC60044-1(IEC61869-1&2)

 

Specification:

Type

Rated primary

voltage
(kV)

Rated secondary voltage
(kV)
Accuracy classes combination

Rated output

(VA)

Thermal limiting current

(VA)

Rated insulation level
(kV)
JDZX16-12R

15/√3

20/√3

22/√3

0.1/√3

0.11/√3

0.2 30 300 12/28/75
0.5 50
1 80

0.1/√3/0.1/3

0.11/√3/0.11/3

0.2/6P 15/50 300
0.5/6P 30/50
0.2/0.5/6P 15/25/50 200/200
0.5/0.5/6P 25/25/50


 

 
3. Outline Drawing:
 
JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage Transformer 0
 
 
 
 
5.Photos:
 
JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage Transformer 1
 
 
JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage Transformer 2
 
 
 

Contact Details
Shenzhen Chuangyin Co., Ltd.

Contact Person: Mr. Dieky Lin

Tel: +86 138 2379 0397

Fax: 86-0755-8600-0614

Send your inquiry directly to us (0 / 3000)

Other Products