Home ProductsMV Voltage Transformer

12kV 24kv 36kv outdoor indoor MV PT epoxy resin single phase with silicone rubber 50/60Hz. Dry type supply power

12kV 24kv 36kv outdoor indoor MV PT epoxy resin single phase with silicone rubber 50/60Hz. Dry type supply power

    • 12kV  24kv 36kv outdoor indoor MV PT epoxy resin single phase with silicone rubber 50/60Hz. Dry type supply power
    • 12kV  24kv 36kv outdoor indoor MV PT epoxy resin single phase with silicone rubber 50/60Hz. Dry type supply power
  • 12kV  24kv 36kv outdoor indoor MV PT epoxy resin single phase with silicone rubber 50/60Hz. Dry type supply power

    Product Details:

    Place of Origin: China
    Brand Name: Shenzhen Chuangyin Co., Lt
    Certification: KEMA/type test report
    Model Number: JDZW1-12R

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pc
    Price: Negetiable
    Packaging Details: Polywood
    Delivery Time: 8days
    Payment Terms: L/C, T/T
    Supply Ability: 80000.00pcs per year
    Contact Now
    Detailed Product Description
    Insulation Type: Dry /Silicone Composite Insulation Voltage: 12kV 24kv 36kv
    Application: Outdoor Indoor Properties: Single Fase
    Applied Standard: IEC 61869-1 &3 (IEC 60044-2) Rated Insulation Level: 12/28/75kV
    Color: Brown Red Material: Epoxy Resin Cast
    Burden: 0.8 Cos Factor Frequency: 50/60HZ

    Chuangyin Voltage Transformer-JDZW1-12R

     

    Description:

     

    This product is fully enclosed outdoor single-phase voltage transformer, epoxy resin and silicone rubber composite insulation support type. The outer sheath and sheds are made of high temperature vulcanized silicone rubber, good hydrophobicity, and highly improved the contamination flashover voltage. It has anti-aging property and with tracking resistance.

     

    VT has inserted MV fuse in the primary terminal, with protective rubber cap for animal protection and sealing function. The transformer is suitable for rated frequency of 50/60Hz, the highest equipment voltage 12kV system. Mainly for measuring, energy metering, protection and auxiliary power supply, etc.

     

    Basic technical data:

     

    1. Installation: Outdoor
    2. Insulation type: Dry, Silicone composite insulation
    3. Highest voltage for equipment Um (r.m.s.) 12kV
    4. Rated power-frequency withstand voltage (r.m.s.): 28kV
    5. Rated lightning impulse withstand voltage (peak): 75kV
    6. Rated frequency: 50Hz / 60Hz
    7. Applied standard: IEC 61869-1 &3 (IEC 60044-2)

     

    Specification:

     

    Rated Primary Voltage

    (kV)

    Rated Secondary Voltage

    (V)

    Accuracy classes combination Rated Burden (VA) Thermal limiting Output (VA)

    Rated Insulation Level

    (kV)

    10

    11

    100

    110

    115

    120

    220

    240

    0.2 15 500 12/28/75
    0.5 50
    0.5/3 30/300

     

     

     

     

     

     

     

     

     

     

     

    Contact Details
    Shenzhen Chuangyin Co., Ltd.

    Contact Person: Sales Manager

    Tel: +8613823790397

    Send your inquiry directly to us (0 / 3000)

    Other Products