    Installation Site: Outdoor Rated Freequency: 50/60hz
    Standard: IEC60044-1&2 IEC61869-1&2&3 Certificate: KEMA,CE,TUV,SGS
    High Light:

    medium voltage potential transformer

    ,

    single phase voltage transformer

    36kv Out Door Single-Phrase Epoxy Resin Type

     

     

     

    1.Product Introduction:

    This single phase combined CT&VT consists of one semi-insulation VT and one CT, VT connected with CT terminal P1, CT series connected with phase A(B,C). Secondary leads in junction box is easy for wiring and testing. Use epoxy resin insulation stunt structure for outdoor installation. Applicable for highest voltage for equipments no more than 40.5kV for current/voltage measurement in power system.

     

     

    2.Technical Data:

     

    1 Installation site:  Outdoor

    2 Rated Frequency: 50/60hz

    3 Burden Power Factor :  cosθ=0.8(lagging)

    4 Technical Standard Accords with IEC60044-1&2    IEC61869-1&2&3

     

     

    3. Application:

     

    1 Use high properties iron core to meet high accuracy, big burden etc.

    2 Use epoxy resin cast insulation structure to improve anti-pollution, anti-moisture etc.

    3 Use full-sealed cast insulation type

    4 Outdoor installation

     

    Use for highest voltage for equipments no more than 40.5kV, for current/voltage measurement in power system.

     

     

     

     

    4.Specificaton

    No. Items Unit Index Remarks
    1 Highest Voltage of Equipment kV 40.5, 36  
    2 BIL kV GB:40.5/95/200, IEC36/70/170  
    3 Rated Primary Voltage V 35400/√3  
    4 Rated Secondary Voltage V 100/√3, 100, 120  
    5 Rated Primary Current A 5-1000  
    6 Rated Secondary Current A 1 or 5  
    Remarks

    Standards: GB20840.1-2010 GB20840.3-2013 GB20840.2-2014

    IEC61869-1:2007 IEC61869-2:2012 IEC61869-3:2011

     

     

     

    Model Voltage Ratio(kV) Accuracy Class Rated Burden(VA) Current Ratio(A) Accuracy Class Rated Burden(VA)
    JLDZXW1-36

    35.4/√3/0.12

    35.4/√3/0.1

    35.4/√3/0.1/√3

    0.2

    0.5

    25

    50

    20-40/5

    0.2S

    0.5S

    12.5
    50-100/5
    400-800
    500-1000
     

    5.Outline Drawing

    OutDoor MV Voltage Transformer Single Phrase Epoxy Resin Type 0OutDoor MV Voltage Transformer Single Phrase Epoxy Resin Type 1

     

    OutDoor MV Voltage Transformer Single Phrase Epoxy Resin Type 2

     

     

     

     

    5.Photos

     

     

     

     

     

     

     

    Contact Details
    Shenzhen Chuangyin Co., Ltd.

    Contact Person: Sales Manager

    Tel: +8613823790397

    Send your inquiry directly to us (0 / 3000)

    Other Products