Place of Origin: | Shenzhen |
Brand Name: | Chuangyin |
Certification: | Kema,CE,SGS,TUV |
Model Number: | LZZBJ10-24 |
Minimum Order Quantity: | 1set |
---|---|
Packaging Details: | Plywood |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 36,000,00pcs per year |
Rated Insulation Level: | 24/50/125 Kv | Installation Site: | Indoor |
---|---|---|---|
Type: | Epoxy Resin Dry Type | Material: | Cast |
Ratio: | 15-1500/5 | Ustage: | Measuring And Protection |
High Light: | medium voltage current transformer,single phase current transformer |
24kv Indoor Single-Phrase Current Transformer Epoxy Resin for Measuring
1.Product Introduction:
LZZBJ10-17.5/24 current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omnidirectional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective relaying in the electrical system with the rated frequency 50- 60Hz and highest voltage for equipment 24kV
2. Technical Data:
Main technical parameter
1. Rated insulation voltage: 24/50/125kV etc.
2. Rated frequency: 50/60hz
3. Installation Site: Indoor
4. Standards: IEC60044-1(IEC61869-1&2)
Two Secondary Single Ratio
Rated transformation ratio(A) |
Accuary classes combination |
Rated output(VA)
|
(ALF) |
(FS) |
Short-time thermal current Ith(kA/S) | Rated dynamic current Idyn(kA) | ||
Measuring |
Protective |
|||||||
0.2(S) | 0.5 | 10P | ||||||
15/5 …… 200/5 |
0.2(S)/0.2(S) 0.2(S)/0.5 0.5/0.5 0.2(S)/10P 0.5/10P
|
10 | 15 |
10
15
|
10
|
5 (10) |
100I1n | 250I1n |
300/5 | 25 | 63 | ||||||
400/5 | 31.5 | 80 | ||||||
500/5 | 40 | 100 | ||||||
600/5 | 40 | 100 | ||||||
800/5 | 63 | 130 | ||||||
1000/5 | 63 | 130 | ||||||
1500/5 | 80 | 160 |
Two Secondary Double Ratio
Rated transformation ratio(A) |
Accuary classes combination |
Rated output(VA)
|
(ALF) |
(FS) |
Short-time thermal current Ith(kA/S) | Rated dynamic current Idyn(kA) | ||
Measuring |
Protective |
|||||||
0.2(S) | 0.5 | 10P | ||||||
15-30/5 20-40/5 …… 200-400/5 |
0.2(S)/0.2(S) 0.2(S)/0.5 0.5/0.5 0.2(S)/10P 0.5/10P
|
10 | 15 |
10
15
|
10
|
5 (10) |
75I1n | 187.5I1n |
300-600/5 | 31.5 | 80 | ||||||
500-1000/5 | 40 | 100 | ||||||
600-1200/5 | 50 | 130 | ||||||
750-1500/5 | 80 | 160 |
Contact Person: Sales Manager
Tel: +8613823790397
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed
36kv Indoor Epoxy resin cast current transformer MV LRZ3-36G Chuangyin
Chuangyin 12kV MV CT Current Transformer for Air Insulation Switchgear
100A/40mA Split Core Current Transformer Open type CT CY-KCT01
Clamp On Split Core Current Transformer Open Distributed Measurement Systems
Epoxy Resin Split Core Current Transducer JDZ-17.5(24) Voltage Transformer Waterproof CT
500A 50/60Hz Open type Split Core Current Transformer Smart Logger
35kV 2# And 3# Plug In euromold termination kit Connector For PT
Epoxy Resin Cast Plug In Bushing GIS IEC 42KV 800A /1250A For Outdoor
42KV 800A /1250A Outdoor GIS Plug In Bushing IEC Epoxy Resin