| Place of Origin: | Shenzhen |
| Brand Name: | Chuangyin |
| Certification: | KEMA,SGS,TUV,UL |
| Model Number: | CY-EVTDC3 |
| Minimum Order Quantity: | 1set |
|---|---|
| Price: | Negetiable |
| Packaging Details: | 36,000,00pcs per year |
| Payment Terms: | L/C, T/T, D/P, D/A, Western Union, MoneyGram |
| Supply Ability: | 36,000,00pcs per year |
| Insulation Level: | 12/42/75kv | Ceertificate: | KEMA,SGS,TUV,UL |
|---|---|---|---|
| Installation Site: | Indoor | Frequency: | 50hz/60hz |
| Highlight: | medium voltage transformer,single phase voltage transformer |
||
Electric voltage transformer/voltage Sensor/LPVT (Cable Connector type)
1 Apply to
≤24kV busbar connecting system with screened separable connector
Application
♦ Voltage sensor apply to voltage measurement of connecting busbar with screened cable connector in medium voltage gas insulation switchgear of smart grid;
♦ Voltage sensor should be installed on the back of the screened cable connector to replace the position of original rear connector.
3. Technical Data:
| Model | CY-EVTDC3-10 | CY-EVTDC3-20 | |
| Max. system voltage | 12kV | 24kV | |
| Insulation level | 12/42/75kV | 24/50/125kV | |
| lighting impulse withstand voltage | 75kV | 125kV | |
| Rated voltage ratio | phase voltage | (10000/V3)/ C3.25/V3) V | (20000/V3)/ (3.25/V3) V |
| zero sequence voltage | (10000/V3)/ (6.5/3) V | (20000/V3)/ C6.5/3) V | |
| Phase voltage- Measuring Accuracy | 0.5 | 0.5 | |
| zero sequence voltage-Protection Accuracy | 1 (3P) | 1 C3P) | |
| Burden (load resistance) | 10MQ | ||
| Rated voltage factor | 1.2Un continue /1.9Un/8h | ||
| Frequency | 50/60 Hz | ||
| Operating temperature | -40°C to +70°C | ||
| LPVT type | Phase voltage + Zero sequence VT | ||
| Installation method and size | rear connector type voltage transformer | ||
| I EC rear cable connector type 15kV/630A | IEC rear cable connector type 24kV/630A | ||
| Standard | GB/T 20840.7 (GB/T 20840.6) C 60044-7 (IEC 61869-6) | ||
| Connecting type | aviation plug—lead terminal | ||
| Connecting cable | RVSP Shield line L = 3 m (length can be customized) | ||
4. Outline Drawing:
![]()
Contact Person: Mr. Dieky Lin
Tel: +86 138 2379 0397
Fax: 86-755-3987544
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed
36kv Indoor Epoxy resin cast current transformer MV LRZ3-36G Chuangyin
Chuangyin 12kV MV CT Current Transformer for Air Insulation Switchgear
100A/40mA Split Core Current Transformer Open type CT CY-KCT01
Clamp On Split Core Current Transformer Open Distributed Measurement Systems
Epoxy Resin Split Core Current Transducer JDZ-17.5(24) Voltage Transformer Waterproof CT
500A 50/60Hz Open type Split Core Current Transformer Smart Logger
35kV 2# And 3# Plug In euromold termination kit Connector For PT
Epoxy Resin Cast Plug In Bushing GIS IEC 42KV 800A /1250A For Outdoor
42KV 800A /1250A Outdoor GIS Plug In Bushing IEC Epoxy Resin