Place of Origin: | China |
Brand Name: | CY-Group |
Certification: | KEMA CE ISO SGS TUV UC3 |
Model Number: | CYS-AST-15/200 |
Minimum Order Quantity: | 1pcs |
---|---|
Price: | NEGOTIABLE |
Packaging Details: | Plymood |
Delivery Time: | 3-8 days |
Payment Terms: | L/C, TT,D/A,D/P |
Supply Ability: | 6000000pcs/year |
Material: | RUBBER | Voltage Class: | 15 KV |
---|---|---|---|
Voltage Rating: | 8.3/14.4 KV | Rated Current: | 200 A |
AC Withstand Voltage 5min: | 39 KV | DC Withstand Voltage 15min: | 35 KV |
Partial Discharge: | 15 KV, ≤10 PC | BIL: | 95 KV |
Thermal Current: | 10 KA, 0.6 S | Dynamic Current: | 20 KA, 10 Ms |
Cable Section: | 35 To 120mm2 | ||
High Light: | t joint connector,cable accessories |
Busbar Connection System 200A, 15 kV Class Loadbreak Feed-thru Bushing Insert
Application
Chuangyin® Loadbreak Feed-thru Bushing Insert is widely applicable for connecting into a standard 200A bushing well, as its two electrically interconnected bushing interfaces. It can convert radial-feed transformers to feedthru transformers and add in-line arrester protection if needed.
The interface complys with IEEE standard 386, 8.3/14.4 kV, 200 A loadbreak design.
Features
Made of high quality EPDM rubber
With two electrically interconnected bushing interfaces
Fully shielded, insulated and submersible connection for loadbreak system
Torque limit ratchet prevents the bushing well stud from breaking during installation
100% factory tested
In compliance with IEC standard 386
Construction
1. Insulating Layer
2. Torque Limit Ratchet
3. Semi-conducting Shield
4. Probe
5. Indicator Ring
6. Arc Quenching Rod
7. Thread
8. Locking Groove
Technical Data
Item | Parameters |
Voltage Class | 15 kV |
Voltage Rating | 8.3/14.4 kV |
Rated Current | 200A |
AC Withstand Voltage 5min | 39 kV |
DC Withstand Voltage 15min | 35 kV |
Partial Discharge | 15 kV, ≤10 pC |
BIL | 95 kV |
Thermal Current | 10 kA, 0.6 s |
Dynamic Current | 20 kA, 10 ms |
Kit Contents
Feed-thru Bushing Insert
Dustproof Cap
Bail Assembly
Wipers
Silicone Grease
Installation Instruction
Certificate
Probe
Certificate
Ordering Instructions
Product | Part Number |
15 kV, 200A Feed-thru Bushing Insert | CYS-AST-15/200 |
Contact Person: Mr. Dieky Lin
Tel: +86 138 2379 0397
Fax: 86-0755-8600-0614
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed
36kv Indoor Epoxy resin cast current transformer MV LRZ3-36G Chuangyin
Chuangyin 12kV MV CT Current Transformer for Air Insulation Switchgear
100A/40mA Split Core Current Transformer Open type CT CY-KCT01
Clamp On Split Core Current Transformer Open Distributed Measurement Systems
Epoxy Resin Split Core Current Transducer JDZ-17.5(24) Voltage Transformer Waterproof CT
500A 50/60Hz Open type Split Core Current Transformer Smart Logger
35kV 2# And 3# Plug In euromold termination kit Connector For PT
Epoxy Resin Cast Plug In Bushing GIS IEC 42KV 800A /1250A For Outdoor
42KV 800A /1250A Outdoor GIS Plug In Bushing IEC Epoxy Resin