| Place of Origin: | China |
| Brand Name: | CY-Group |
| Certification: | KEMA CE ISO SGS TUV UC3 |
| Model Number: | CYS-AFZH-15/600/200 |
| Minimum Order Quantity: | 1pcs |
|---|---|
| Price: | NEGOTIABLE |
| Packaging Details: | Plymood |
| Delivery Time: | 3-8 days |
| Payment Terms: | L/C, TT,D/A,D/P |
| Supply Ability: | 6000000pcs/year |
| Material: | RUBBER | Voltage Class: | 15 KV |
|---|---|---|---|
| Voltage Rating: | 8.3/14.4 KV | Rated Current: | 200 A |
| AC Withstand Voltage 5min: | 39 KV | DC Withstand Voltage 15min: | 35 KV |
| Partial Discharge: | 15 KV, ≤10 PC | BIL: | 95 KV |
| Thermal Current: | 10 KA, 0.6 S | Dynamic Current: | 20 KA, 10 Ms |
| Cable Section: | 35 To 120mm2 | ||
| Highlight: | load break elbows,cable accessories |
||
Busbar Connection Ssytem 200A, 15 kV Class Deadbreak Reducing Tap Plug (RTP) with Bushing Extender
Application
Chuangyin® Reducing Tap Plug is widely applicable for the transition of a 600 A deadbreak system to a 200 A deadbreak or loadbreak system. Assembled with Bushing Extender, provides two in-line elbow interfaces. It can be used for test purpose. The 200A interface allows for live test, visible ground, addition of a 200A tap, or installation of an elbow arrester.
The interface complys with IEEE standard 386, 8.3/14.4 kV, 600 A & 200 A deadbreak design.
Features
* Made of high quality EPDM rubber
* Transition of a 600 A deadbreak system to a 200 A deadbreak or loadbreak system, with the 600A interface connecting to bushing or junction and 200A loadbreak bushing interface
* Fully shielded, submersible connection for deadbreak system
* 100% factory tested
* In compliance with IEC standard 386
Construction
![]()
![]()
1. Reducing Tap Plug (RTP)
2. Insulating Layer
3. Semi-conducting Insert
4. Grounding Tab
5. Conductive Ring
6. Semi-conducting Shield
Technical Data
| Item | Parameters |
| Voltage Class | 15 kV |
| Voltage Rating | 8.3/14.4 kV |
| Rated Current | 200 A |
| AC Withstand Voltage 5min | 39 kV |
| DC Withstand Voltage 15min | 35 kV |
| Partial Discharge | 15 kV, ≤10 pC |
| BIL | 95 kV |
| Thermal Current | 10 kA, 0.6 s |
| Dynamic Current | 20 kA, 10 ms |
Kit Contents
Bushing Extender
Reducing Tap Plug (RTP)
Bolt
Wipers
Silicone Grease
Installation Instruction
Certificate
Ordering Instructions
| Product | Part Number |
| 15kV Reducing Tap Plug (RTP) | CYS-AFZH-15/600/200 |
Contact Person: Mr. Dieky Lin
Tel: +86 138 2379 0397
Fax: 86-0755-8600-0614
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed
36kv Indoor Epoxy resin cast current transformer MV LRZ3-36G Chuangyin
Chuangyin 12kV MV CT Current Transformer for Air Insulation Switchgear
100A/40mA Split Core Current Transformer Open type CT CY-KCT01
Clamp On Split Core Current Transformer Open Distributed Measurement Systems
Epoxy Resin Split Core Current Transducer JDZ-17.5(24) Voltage Transformer Waterproof CT
500A 50/60Hz Open type Split Core Current Transformer Smart Logger
35kV 2# And 3# Plug In euromold termination kit Connector For PT
Epoxy Resin Cast Plug In Bushing GIS IEC 42KV 800A /1250A For Outdoor
42KV 800A /1250A Outdoor GIS Plug In Bushing IEC Epoxy Resin