Send Message
Home ProductsMV Current Transformer

12kV MV Voltage Transformer Single Phase 50 / 60Hz For Measuring / Protective

12kV MV Voltage Transformer Single Phase 50 / 60Hz For Measuring / Protective

  • 12kV MV Voltage Transformer Single Phase 50 / 60Hz For Measuring / Protective
12kV MV Voltage Transformer Single Phase 50 / 60Hz For Measuring / Protective
Product Details:
Place of Origin: China
Brand Name: Chuangyin
Certification: KEMA/type test report
Model Number: JDZXW5-12
Payment & Shipping Terms:
Minimum Order Quantity: 1-100PCS
Price: Negotiable
Packaging Details: Plywood
Delivery Time: 5-10 workdays
Payment Terms: L/C, T/T
Supply Ability: 36000PCS/YEAR
Contact Now
Detailed Product Description
Insulation Type: Dry Type/Epoxy Cast Installation: Outdoor
Voltage: 12kV Rated Frequency: 50Hz/60Hz
Standard: IEC/GB Rated Frequency: 50Hz Or 60Hz
High Light:

medium voltage current transformer

,

medium voltage instrument transformers

Chuangyin Voltage Transformer-JDZXW5-12

 

Description:

 

Epoxy resin casting and full-closed construction, single-pole for phase to ground connection, It is widely used for measuring voltage, electric energy and protective relaying in the sing-phase or three phase power system with the frequency 50Hz or 60Hz and highest voltage for equipment 12kV

 

Basic technical data:

 

1. Installation: outdoor

2. Insulation type: dry, epoxy cast

3. Highest voltage for equipment Um (r.m.s.) 12kV

4. Rated power-frequency withstand (induced) voltage (r.m.s.): 28kV

5. Rated lightning impulse withstand voltage (peak): 75kV

5. Rated frequency: 50Hz or 60Hz

6. Applied standard: IEC 61869-1&3 (IEC 60044-2)

 

 

Shenzhen Chuangyin Co., Ltd has three manufacturing bases ,they are Jiangxi Chuangyin Co.,Ltd, Zhuhai Chuangyin Co.,Ltd and Joint-Venture Adex-Chuangyin Electric Co.,Ltd(Bangladesh); with 40,000 square meters of modern standard workshop and a number of first-class production line and test equipments, by many years’ experience for three dedicated engineering teams, the annual output of medium &low current transformer and voltage transformer is more than 36000 sets and CT, relay is more than 25 million pcs.

 

Specification:

 

Rated Primary Voltage(kV) Rated Secondary Voltage(V) Accuracy classes combination Rated Burden (VA) Thermal limiting Output (VA)

Rated Insulation Level

(kV)

Measuring Protective

10/√3

11/√3

100/√3

110/√3

100/3

110/3

0.2 10 300 12/28/75
0.5 25
1 50
0.2/3P 10/50 200
0.5/3P 25/50

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact Details
Shenzhen Chuangyin Co., Ltd.

Contact Person: Mr. Dieky Lin

Tel: +86 138 2379 0397

Fax: 86-0755-8600-0614

Send your inquiry directly to us (0 / 3000)