Place of Origin: | China |
Brand Name: | Chuangyin |
Certification: | Type test report |
Model Number: | CYSESBQJ(01)-15/400-25-50 |
Minimum Order Quantity: | 1 |
---|---|
Price: | negotiable |
Packaging Details: | Carton packing for one sets, one set including three piece with Components |
Delivery Time: | Within 7 days |
Payment Terms: | L/C, T/T, Western Union, MoneyGram |
Supply Ability: | 1000Pcs/week |
Material: | Insulating Plug | Color: | Black |
---|---|---|---|
Rated Voltage: | 15kv, 24kv And 35kv | Partial Discharge: | 15 KV, ≤10 PC; 24 KV, ≤10 PC;45 KV, ≤10 PC |
High Light: | plastic tee connector,straight connector |
CYSESBQJ(01)-15/400-25-50 400A 15kv,24kv and 35kv IEC Tee Connector Separable Connectors
Chuangyin® Tee Connector is widely applicable for terminating polymeric insulated cable to dead front apparatus such as transformers, switchgear, and other equipment in 400 A power network.
Cable section: 25 to 630mm2
Voltage rating: 6/10 (12) kV, 6.35/11 (12) kV, 8.7/15 (17.5) kV, 12/20 (24) kV, 12.7/22 (24) kV, 18/30 (36) kV, 20.8/36 (42) kV, 21/35 (40.5) kV, 26/35 (40.5) kV
The interface designed to comply with EN 50180 / EN 50181 630 A interface type B and HD 629.1, IEC 60502.4, GB/T 12706.4 etc.
Construction
1. Insulating Plug
2. End Cap
3. Grounding Tab
4. Lug Stud
5. Conducting Insert Adapter 6. Insulating Layer
7. Conducting Shield
Technical Data
Item | Parameters | ||
Voltage Class | 15 kV | 24 kV | 35 kV |
Rated Current | 400 A | 400 A | 400 A |
AC Withstand Voltage 5min | 39 kV | 54 kV | 117 kV |
DC Withstand Voltage 15min | 35 kV | 48 kV | 104 kV |
Partial Discharge | 15 kV, ≤10 pC | 20 kV, ≤10 pC | 45 kV, ≤10 pC |
BIL | 95 kV | 125 kV | 200 kV |
Screen Resistance | ≤ 5000 Ω | ≤ 5000 Ω | ≤ 5000 Ω |
Cable Section | 25-400 mm2 | 35-500 mm2 | 50-630 mm2 |
Interface Type | B | B | B |
Kit Contents
Tee Connector | Wrench Stud |
Lug | Sand Bar |
Adapter | Semi-conducting Tape |
End Cap | Silicone Grease |
Insulating Plug | Wipers |
Probe | Tape |
Bail Assembly | Installation Instruction |
Ordering Instructions
Part Number | Cable Section (mm2) | Diameter over Insulation (mm) | Code |
CYS-E(S)BQJ(01)-15/400-25-50 | 25-50 | 16-20 | A |
CYS-E(S)BQJ(01)-15/400-70-95 | 70-95 | 20-23.1 | B |
CYS-E(S)BQJ(01)-15/400-120-150 | 120-150 | 23-26.1 | C |
CYS-E(S)BQJ(01)-15/400-185-240 | 185-240 | 25.8-30 | D |
CYS-E(S)BQJ(01)-15/400-300 | 300 | 30.4-32.3 | E |
CYS-E(S)BQJ(01)-15/400-400 | 400 | 33-35.4 | F |
CYS-E(S)BQJ(01)-24/400-35-50 | 35-50 | 18-22 | A |
CYS-E(S)BQJ(01)-24/400-70-95 | 70-95 | 22-25.1 | B |
CYS-E(S)BQJ(01)-24/400-120-150 | 120-150 | 25-28.1 | C |
CYS-E(S)BQJ(01)-24/400-185-240 | 185-240 | 27.8-30 | D |
CYS-E(S)BQJ(01)-24/400-300 | 300 | 32.4-34.4 | E |
CYS-E(S)BQJ(01)-24/400-400 | 400 | 35-37.4 | F |
CYS-E(S)BQJ(01)-24/400-500 | 500 | 38.4-40.3 | G |
CYS-E(S)BQJ(01)-40.5/400-50-70 | 50-70 | 30-33.4 | A |
CYS-E(S)BQJ(01)-40.5/400-95-120 | 95-120 | 33.6-36.6 | B |
CYS-E(S)BQJ(01)-40.5/400-150-185 | 150-185 | 36.4-40 | C |
CYS-E(S)BQJ(01)-40.5/400-240-300 | 240-300 | 40-44.3 | D |
Contact Person: Mr. Dieky Lin
Tel: +86 138 2379 0397
Fax: 86-0755-8600-0614
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed
36kv Indoor Epoxy resin cast current transformer MV LRZ3-36G Chuangyin
Chuangyin 12kV MV CT Current Transformer for Air Insulation Switchgear
100A/40mA Split Core Current Transformer Open type CT CY-KCT01
Clamp On Split Core Current Transformer Open Distributed Measurement Systems
Epoxy Resin Split Core Current Transducer JDZ-17.5(24) Voltage Transformer Waterproof CT
500A 50/60Hz Open type Split Core Current Transformer Smart Logger
35kV 2# And 3# Plug In euromold termination kit Connector For PT
Epoxy Resin Cast Plug In Bushing GIS IEC 42KV 800A /1250A For Outdoor
42KV 800A /1250A Outdoor GIS Plug In Bushing IEC Epoxy Resin