Send Message
Home ProductsMV Voltage Transformer

12kv Three - Phase Mv Voltage Transformer Pt Bushing Type Ieee Mv / Lv / Hv

12kv Three - Phase Mv Voltage Transformer Pt Bushing Type Ieee Mv / Lv / Hv

  • 12kv Three - Phase Mv Voltage Transformer Pt  Bushing Type Ieee Mv / Lv / Hv
  • 12kv Three - Phase Mv Voltage Transformer Pt  Bushing Type Ieee Mv / Lv / Hv
  • 12kv Three - Phase Mv Voltage Transformer Pt  Bushing Type Ieee Mv / Lv / Hv
  • 12kv Three - Phase Mv Voltage Transformer Pt  Bushing Type Ieee Mv / Lv / Hv
12kv Three - Phase Mv Voltage Transformer Pt  Bushing Type Ieee Mv / Lv / Hv
Product Details:
Place of Origin: Shenzhen
Brand Name: Chuangyin
Certification: Kema,CE,SGS,TUV
Model Number: JSZWF16-12R
Payment & Shipping Terms:
Minimum Order Quantity: 1set
Price: negotiable
Packaging Details: Carton packing for one sets, one set including three piece with Components
Delivery Time: Within 7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 36,000,00pcs per year
Contact Now
Detailed Product Description
Usetage: Protective Relaying In Single-Phase Or Three-Phase Construction: Full-enclosed
Termal Limit Output: 1000VA Zero-Sequence: 0.1
Technical Standard: IEC60044-2 Type: Epoxy Resin Cast
Usage: Measuring Protected
High Light:

medium voltage transformer

,

medium voltage potential transformer

MV Voltage Transformer 12kV Three-Phase MV Voltage Transformer PT BUSHING TYPE IEEE MV/LV/HV​


1. Product Introduction:
 

Epoxy resin casting and full enclosed construction, is used indoor for measuring voltage, electric energy and protective relaying in single-phase or three-phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipment 12kV.
The product has the feature of high reliability, low magnetism of core, large creepage distance of external insulation and maintenance free etc.
The primary cone accords with IEEE 386-2006 figure 7

 

Technical Data

 

1. Installation site: Indoor
2. Rated frequency: 50/60Hz
3. Load power factor: cos=0.8 (lagging)
4. Technical standard accords with: IEC 60044-2
                                                         IEC 61869-1 &3

Specification:

 

Rated primary

voltage (kV)

Rated secondary voltage (kV) Accuracy classes combination

Rated output

(VA)

Thermal limiting current

(VA)

10/√3

 

0.1/√3; 0.1

0.2/3P 25/100 1000
0.5/3P 60/100
1/3P 150/100

 

0.1√3/0.1√3;0.1

 

 

0.2/0.2/3P 20/20/100
0.2/0.5/3P 20/30/100
0.5/0.5/3P
30/30100  

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

 