Send Message
Home ProductsMV Voltage Transformer

PT Epoxy Resin Type MV Voltage Transformer With Fuse IEEE Bushing KEMA Proved

PT Epoxy Resin Type MV Voltage Transformer With Fuse IEEE Bushing KEMA Proved

  • PT Epoxy Resin Type MV Voltage Transformer With Fuse IEEE Bushing KEMA Proved
  • PT Epoxy Resin Type MV Voltage Transformer With Fuse IEEE Bushing KEMA Proved
PT Epoxy Resin Type MV Voltage Transformer With Fuse IEEE Bushing KEMA Proved
Product Details:
Place of Origin: Shenzhen
Brand Name: Chuangyin
Certification: Kema,CE,SGS,TUV
Model Number: JSZV16-24R
Payment & Shipping Terms:
Minimum Order Quantity: 1set
Price: negotiable
Packaging Details: Carton packing for one sets, one set including three piece with Components
Delivery Time: Within 7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 36,000,00pcs per year
Contact Now
Detailed Product Description
Usetage: Switch Cabinet To Measure The Voltage, Electric Energey Highest Voltage For Equipment: 17.5/24KV
Rated Primary Voltage: 22KV Rated Insulation Level: 24/50/125KV
Material: With Fuse Rated Frequency: 50/60HZ
Standard: IEEE Structure: Toroidal Coil Structure
High Light:

medium voltage transformer

,

single phase voltage transformer

MV Voltage Transformer 12kV Three-Phase PT Epoxy Resin Type with fuse IEEE Bushing KEMA Proved Power Usage​


1.Product Introduction:
 

JSZV16-24R voltage transformer, epoxy resin casting and full enclosed construction, is used indoor for measuring current, electric energy and protective relaying in single-phase or three-phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipement 12kV.

The product has the feature of high reliability, low magnetism of core, large creepage distance of external insulation and maintenance free etc.

 

Main technical parameter

1. Highest voltage for equipment: 12kV

2. Rated primary voltage: 11kV

3. Rated secondary voltage: 100/220V or 110/220V or 100V or 110V

4. Technical standard accords with IEC 60044-2:2003 Part2 Instrument transformers-Part2: inductive voltage transformers

 

Type

Rated primary

voltage (kV)

Rated secondary voltage (kV) Accuracy classes combination

Rated output

(VA)

Thermal limiting current

(VA)

Rated insulation level(kV)
JSZV16-24R 11

0.1

0.11

0.2 25 600 12/28/75
0.5 50
1 100

0.1/0.1

0.11/0.11

0.2/0.2 15/15 300
0.2/0.5 15/30

0.1/.022

0.11/0.22

0.2/6P(3P) 15/300 600
0.5/6P(3P) 25/300

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

 

 

Outline drawing

 

 
PT Epoxy Resin Type MV Voltage Transformer With Fuse IEEE Bushing KEMA Proved 0
 
 
 
 
 
 
 
 

Contact Details
Shenzhen Chuangyin Co., Ltd.

Contact Person: Mr. Dieky Lin

Tel: +86 138 2379 0397

Fax: 86-0755-8600-0614

Send your inquiry directly to us (0 / 3000)