Send Message
Home ProductsMV Voltage Transformer

12kV Indoor Medium Voltage Transformer PT With Fuse IEEE Bushing Enclosed

12kV Indoor Medium Voltage Transformer PT With Fuse IEEE Bushing Enclosed

  • 12kV Indoor Medium Voltage Transformer PT With Fuse IEEE Bushing Enclosed
  • 12kV Indoor Medium Voltage Transformer PT With Fuse IEEE Bushing Enclosed
12kV Indoor Medium Voltage Transformer PT With Fuse IEEE Bushing Enclosed
Product Details:
Place of Origin: Shenzhen
Brand Name: Chuangyin
Certification: Kema,CE,SGS,TUV
Model Number: JSZV18-24RJ
Payment & Shipping Terms:
Minimum Order Quantity: 1set
Price: negotiable
Packaging Details: Carton packing for one sets, one set including three piece with Components
Delivery Time: Within 7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 36,000,00pcs per year
Contact Now
Detailed Product Description
Feature: Improve The Filth And Moisture Resistance Highest Voltage For Equipment: 24KV
Termal Limit Output: 2500VA Rated Primary Voltage: 20/22KV
Technical Standard: 0.2;0.5;1;0.2/0.2;0.2/0.5;0.2/6P;0.5/6P Rated Insulation Level: 24/50/150KV
Type: Three-Phase Standard: IEEE
High Light:

medium voltage potential transformer

,

single phase voltage transformer

12kV Indoor Medium Voltage Transformer PT Epoxy Resin Type with fuse IEEE Bushing Enclosed Support Construction for Switchgear

 
1. Product Introduction:
 

JSZV18-24RJ voltage transformer, is fully enclosed casting insulation structure, the primary winding, secondary winding and the annular core all coating in the epoxy resin casting, The product adds elbow type plug part, improving the filth and moisture resistance, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 24 kV

 

Main technical parameter

1. Rated primary voltage: 20kV or 22kV

2. Rated secondary voltage:100V,100/100V,100/220V

3. Rated voltage of residual voltage windings:100/ 3V ,110/ 3V, 115/ 3V, 120/ 3V

4. Burden power factor: cosΦ=0.8(lagging)

5. Standards: IEC60044-2.2003 or IEC61869-1&3

 

Other technical parameters pls see as follow:

 

Type

Rated primary

voltage (kV)

Rated secondary voltage (kV) Accuracy classes combination

Rated output

(VA)

Thermal limiting current

(VA)

Rated insulation level(kV)
JSZV18-24RJ

20

22

0.1

0.11

0.2 40 2000 24/50/150
0.5 80
1 100

0.1/0.1

0.11/0.11

0.2/0.2 20/20 500/500
0.2/0.5 20/30

0.1/0.22

0.11/0.22

0.2/6P(3P) 50/800 800/2000
0.5/6P(3P) 50/800

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

 

Outline drawing

 

 
12kV Indoor Medium Voltage Transformer PT With Fuse IEEE Bushing Enclosed 0

Contact Details
Shenzhen Chuangyin Co., Ltd.

Contact Person: Mr. Dieky Lin

Tel: +86 138 2379 0397

Fax: 86-0755-8600-0614

Send your inquiry directly to us (0 / 3000)

Other Products