Type: | Clamp-on Current Transformer | Feature: | Simple And Quick Installation In Small Space |
---|---|---|---|
Ampere: | 500A | Application: | General Measurement |
Characteristic: | Excellent Linearity | ||
High Light: | split core ac current sensor,split core current sensor |
100-3000A 50/60Hz Clamp-on Current Transformer Current Transformer / Open type CY-QCT01
1.Product Introduction:
QCT04-12'clamp-on current transformer is easily installed in small spaces (measurement environment) and no need to remove the main busbar or cable. It complys with the CE standard and meets the 300V CAT III safety grade.
Feature:
1. Flexible and light weight, pretty appearance
2. Simple and quick installation in small space
3. Excellent linearity
4. Maximum measured current is 130A
General Data:
Operating temperature & humidity: 0 - 500C (32 - 122 0 F), _< 80% RH (no condensate)
Storage Temperature & Humidity: -10 - + 600C (14 -140 0 F), <_ 80% RH (no condensate)
Operating environment: indoor, up to 2000 meters above sea level.
Safety level standards: IEC 61010-1: 2001. 300 V CAT III
Application:
General measurement and protection for strong mobility or space-constrained or uninterrupted power
systems.
Power instrumentation, electronic multi-function energy meter and field calibrator, instrumentation measurement and protection.
Dimension And Schematic:
Usage Instruction:
Attention:
1. Please note that prolonged over current use may damage the product.
2. Do not store or use this product in the environment of directly exposed to sunlight, high temperature or high
humidity or condensation. The product may be damaged, the insulation will be deteriorated in these
condition.
3. Do not drop the product or avoid other mechanical shocks, which may damage the surface of the core
and affect the measurement accuracy.
4. Keep the jaws & the core slit without other outer matter, which may affect the clamping action.
5. Holding Clamp Closed When storage, in order to avoid dust or dirt buildup on the core engagement surface,
other outer maters may affect the measurement performance.
6. When disconnecting the BNC connector, be sure to rotate the lock before releasing the connector. Pulling the
connector or pulling the cable (under lock unreleased) will damage the connector.
7. To prevent damage to the connected instrument, do not connect or disconnect the sensor in the event of
charging (working statue) .
8. Note: Only one wire can be clamped in the center of the chuck. If you clamp the single-phase (2-wire) or
three-phase (3-wire) cable at the same time, the device will not generate any readings.
9. The above parameters are only for reference as typical data, customer-made is subject to customer's request.
Contact Person: Mr. Dieky Lin
Tel: +86 138 2379 0397
Fax: 86-0755-8600-0614
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed
36kv Indoor Epoxy resin cast current transformer MV LRZ3-36G Chuangyin
Chuangyin 12kV MV CT Current Transformer for Air Insulation Switchgear
100A/40mA Split Core Current Transformer Open type CT CY-KCT01
Clamp On Split Core Current Transformer Open Distributed Measurement Systems
Epoxy Resin Split Core Current Transducer JDZ-17.5(24) Voltage Transformer Waterproof CT
500A 50/60Hz Open type Split Core Current Transformer Smart Logger
35kV 2# And 3# Plug In euromold termination kit Connector For PT
Epoxy Resin Cast Plug In Bushing GIS IEC 42KV 800A /1250A For Outdoor
42KV 800A /1250A Outdoor GIS Plug In Bushing IEC Epoxy Resin