Place of Origin: | ShenZhen |
Brand Name: | Chuangyin |
Certification: | Test Report |
Model Number: | CY-FLXK-XX |
Minimum Order Quantity: | 1set |
---|---|
Price: | negotiable |
Packaging Details: | Carton packing for one sets, one set including three piece with Components |
Delivery Time: | Within 7 days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 36,000,00pcs per year |
Type: | Zero-Sequence Current Transformer | Feature: | Ring Type Open Structure |
---|---|---|---|
Usage: | Electrical Instrumentation | Application: | Can Be Adjusted According To The Test Cable Size |
Characteristic: | NO Need To Disconnect The Busbar When Power Off | Function: | General Measurement |
High Light: | split core ac current sensor,split core current sensor |
100A 50/60Hz Sensor Split Core Current Transformer DC/AC Current Transformer
Introduction:
CY-FLXK-XX Flexible Steel Strips Zero-Sequence Current Transformer is specially designed for assembling and
disconnecting the existing main busbar or cable electrical installation, the secondary output is mV voltage signal,
and energy meter, grounding fault indicator, suitable for power meter, switchgear, control cabinet and other
measurement and control equipment. It can detect the grounding fault current in medium voltage distribution
network and monitor the sum current of all three wires. The electronic components of the display unit are combined
with the grounding fault to evaluate the measurement results and protect the electrical safety of the circuit.
Feature:
Protection grade: Ip65;
No need to disconnect the bulbar when power off,
installation fast and convenient;
The appearance is exquisite, the inner window size
may can be adjusted according to the test cable size;
Split core design, ring type open structure, with
puncture and power-taking function.
Application:
Function: General measurement and protection in power systems for mobility or space-intensive or
uninterrupted power systems
Usage: Electrical instrumentation, grounding fault
indicator, instrument measurement and protection
General Data:
Item | Unit | Technical Data |
Highest voltage for equipment | V | 720V |
Power frequency withstand voltage | kV/S | 3kV/60S |
Rate primary current | A | 10-300A |
Environment | Outdoor, Waterproof (IP65) | |
Frequency | Hz | 50/60Hz |
Rated continuous thermal current | 1.2lmax |
Technical Data:
Item | Unit | Technical Data |
Highest voltage for equipment | V | 720V |
Power frequency withstand voltage | kV/S | 3kV/60S |
Rate primary current | A | 10-300A |
Environment | Outdoor, Waterproof (IP65) | |
Frequency | Hz | 50/60Hz |
Rated continuous thermal current | 1.2lmax |
Dimension and Schematic :
Usage Instruction:
Contact Person: Mr. Dieky Lin
Tel: +86 138 2379 0397
Fax: 86-0755-8600-0614
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed
36kv Indoor Epoxy resin cast current transformer MV LRZ3-36G Chuangyin
Chuangyin 12kV MV CT Current Transformer for Air Insulation Switchgear
100A/40mA Split Core Current Transformer Open type CT CY-KCT01
Clamp On Split Core Current Transformer Open Distributed Measurement Systems
Epoxy Resin Split Core Current Transducer JDZ-17.5(24) Voltage Transformer Waterproof CT
500A 50/60Hz Open type Split Core Current Transformer Smart Logger
35kV 2# And 3# Plug In euromold termination kit Connector For PT
Epoxy Resin Cast Plug In Bushing GIS IEC 42KV 800A /1250A For Outdoor
42KV 800A /1250A Outdoor GIS Plug In Bushing IEC Epoxy Resin