Home ProductsMV Voltage Transformer

Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole

Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole

    • Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole
    • Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole
    • Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole
    • Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole
  • Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole

    Product Details:

    Place of Origin: ShenZhen
    Brand Name: Chuangyin
    Certification: Test Report
    Model Number: JDZW3-12R

    Payment & Shipping Terms:

    Minimum Order Quantity: 1set
    Price: negotiable
    Packaging Details: Carton packing for one sets, one set including three piece with Components
    Delivery Time: Within 7 days
    Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability: 36,000,00pcs per year
    Contact Now
    Detailed Product Description
    Load Power Factor: Cos=0.8 (lagging) Secondary Voltage: 110V Or 220V
    Primary Voltage: 11000V Highest Voltage: 12KV
    Installation Site: Outdoor Function: Protective Relaying In Single-Phase Or Three-Phase AC Circuit

     

    12kV Outdoor Single-Phase Epoxy Resin Type MV Voltage Transformer  With Fuse Double Pole

     

    1. Introduction:

     

    Voltage transformer with fully enclosed cast insulation structure, the primary and secondary windings and toroidal cores are all encapsulated in epoxy casting body for large creepage distance and improving resistance to contamination and moisture performance. It is used outdoor for measuring voltage, electric energy and protective relaying in single-phase or three-phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipment 12kV.

     

    2. Technical Data:


    Installation site: Outdoor
    Rated frequency: 50/60Hz
    Load power factor: cosΦ=0.8 (lagging)
    Technical standard accords with: IEC 60044-2

    IEC 61869-1&3

     

     

    3. Specification:

    Item Specification Unit Data
    1 Um kV 12
    2 Rated Insulation Level kV 12/42/75
    3 Rated Primary Voltage V 11000
    4 Rated Secondary Voltage V 110 or 220
     
     
    Model

    Rated Primary Voltage

    (kV)

    Rated Secondary Voltage

    (kV)

    Accuracy Classes combination

    Rated output

    (VA)

    Thermal Limiting Output

    (VA)

    BIL

    (kV)

    JDZW3-12R 11 0.11 0.2 10/20 150 12/28/75
    0.22 0.5 15/300 300
    3 200
    5M 300

    Note:Other specifications can be designed as customized.

     

    Outline drawing:

     

    Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole

     

     
     
     
     

    Contact Details
    Shenzhen Chuangyin Technology Co., Ltd.

    Contact Person: Isabel

    Send your inquiry directly to us (0 / 3000)