Place of Origin: | Shenzhen |
Brand Name: | Chuangyin |
Certification: | IEEE/ANSI,KEMA,CE |
Model Number: | CY-ECTST2 |
Minimum Order Quantity: | 1set |
---|---|
Price: | Negotiable |
Packaging Details: | Plywood |
Payment Terms: | L/C, T/T |
Supply Ability: | 36,000,000pcs per year |
Insulation Level: | 0.66/3kv/(0.72/3kv) | Material: | Epoxy Resin |
---|---|---|---|
Accuracy: | 0.5S(5P10) | Frequency: | 50Hz/60Hz |
High Light: | ct current transformer,instrument potential transformer |
CY-ECTST2 0.72KV Phase current + zero sequence current sensor and Three-phase Low Power Current Sensor
Apply to
≤ 24kV cable (insulated) bus
≤ 0.72kV low voltage non - insulated bus
> Currents sensor is suitable for smart grid low or medium voltage switchgear insulation bus or cable bus measurement.
> Current sensor is mounted on insulated bus bars, shielded cable connectors or similar type insulated conductors.
Model | CY-ECTST2 | |
Max. system voltage (cable bus) | 24kV | |
Insulation level | 0,66/3kV (0,72/3kV) | |
Rated ratio | Phase current | 600A/1V(4 times max ) |
Zero sequence current | 20A/0.2V | |
Accuracy | Phase current | 0.5S(5P10)measure, metering, production compatible |
Zero sequence current | 10P10(<1%@1%~120%In) | |
Short time thermal current | 20xIn | |
Burden (load resistance) | ≥20kΩ | |
Frequency | 50/60 Hz | |
Operating temperature | -40°C to +70°C | |
Current sensor type | Phase current + zero sequence current sensor | |
Installation method and size | core is mounted on the busbar | |
Inner diameter 3-Φ85mm(3-Φ110mm) | ||
bottom installed with screw holes | ||
Standard |
GB/T 20840.8 (GB/T 20840.6) IEC 60044-8 (IEC 61869-6) |
|
Connection type | Air plug - lead terminal | |
Connecting cable | RVSP shielded wire L = 3 m (length can be customized) |
Outline Drawing
Contact Person: Mr. Dieky Lin
Tel: +86 138 2379 0397
Fax: 86-0755-8600-0614
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed
36kv Indoor Epoxy resin cast current transformer MV LRZ3-36G Chuangyin
Chuangyin 12kV MV CT Current Transformer for Air Insulation Switchgear
100A/40mA Split Core Current Transformer Open type CT CY-KCT01
Clamp On Split Core Current Transformer Open Distributed Measurement Systems
Epoxy Resin Split Core Current Transducer JDZ-17.5(24) Voltage Transformer Waterproof CT
500A 50/60Hz Open type Split Core Current Transformer Smart Logger
35kV 2# And 3# Plug In euromold termination kit Connector For PT
Epoxy Resin Cast Plug In Bushing GIS IEC 42KV 800A /1250A For Outdoor
42KV 800A /1250A Outdoor GIS Plug In Bushing IEC Epoxy Resin