Place of Origin: | China |
Brand Name: | CY-Group |
Certification: | KEMA CE ISO SGS TUV UC3 |
Model Number: | CYECVT1-36N |
Minimum Order Quantity: | 1pcs |
---|---|
Price: | NEGOTIABLE |
Packaging Details: | Plymood |
Delivery Time: | 3-8 days |
Payment Terms: | L/C, TT,D/A,D/P |
Supply Ability: | 3600000pcs/year |
Material: | Epoxy Resin | Voltage: | 36kv |
---|---|---|---|
Rated Frequency: | 50Hz | Installation Site: | Indoor |
Rated Primary Voltage (kV): | 35/√3kV | Standard: | IEC60044-2:2003 |
Rated Insulation Level(kV): | 40.5/95/200kV | Accuracy: | 0.2 0.5 1 0.2/0.2 0.5/6P |
Rated Primary Current: | 50-1500A | Rated Burden: | >10kΩ(ECT). >1MΩ(EVT) |
Type: | Measuring Protected | ||
High Light: | instrument potential transformer,ring type current transformer |
Instrument Current Transformer CYECVT1-36N Single Phase Electronic Combined Current and Voltage Transformer Indoor
The products have designed base on IEC60044-8, GB/T20840.8-2007&IEC60044-7,GB/T20840.7-2007 standards, and customers special design service. This series are utilized LPCT&Rogowski coil to meter current in circle, conduct Resistor divider to measure voltage. Installed in any switchgear with High tense voltage below 10kV, compatible with electric instrument, digital measure and protective equipment, able to conduct multifunction such as measure, control, protection and data transmission etc simultaneity.
Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs..
Main technical parameter
1, Rated primary voltage : 35/√3kV
2, Rated primary current : 50-1500A
3, Rated secondary output :
ECT : 4V (measure), 200mV (protection )
EVT : 3.5/√3V, 3.25/√3V or 6.5/√3V
4. Rated Burden: >10kΩ(ECT). >1MΩ(EVT)
5, Rated digital output : 0x2D41( measure),0x01CF(protection)
6, Accuracy for measure winding : 0.2(ECT) ,0.2(EVT)
7, Accuracy for protection winding : 5TPE(ECT),3P(EVT)
8, Rated frequency : 50Hz
9, Rated insulation level : 40.5/95/200kV
10, Rated short time thermal current : 50-200: 150Ipr, 300-1500A :31.5kA/1S
11, Rated dynamic current : 50-200A :375Ipr, 300-1500A :80kA
12, Ambient temperature : -5℃-40℃(indoor)
13, Ambient humidity : ≤RH95%(25℃)
14, Altitude : ≤ 2000m (custom design)
15 , Installation site : indoor
Outline drawing
African Supplier
Contact Person: Mr. Dieky Lin
Tel: +86 138 2379 0397
Fax: 86-0755-8600-0614
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed
36kv Indoor Epoxy resin cast current transformer MV LRZ3-36G Chuangyin
Chuangyin 12kV MV CT Current Transformer for Air Insulation Switchgear
100A/40mA Split Core Current Transformer Open type CT CY-KCT01
Clamp On Split Core Current Transformer Open Distributed Measurement Systems
Epoxy Resin Split Core Current Transducer JDZ-17.5(24) Voltage Transformer Waterproof CT
500A 50/60Hz Open type Split Core Current Transformer Smart Logger
35kV 2# And 3# Plug In euromold termination kit Connector For PT
Epoxy Resin Cast Plug In Bushing GIS IEC 42KV 800A /1250A For Outdoor
42KV 800A /1250A Outdoor GIS Plug In Bushing IEC Epoxy Resin