Send Message
Home ProductsMV Voltage Transformer

36kV Outdoor VT MV Voltage Transformer Epoxy Resin Full Closed Double Pole

36kV Outdoor VT MV Voltage Transformer Epoxy Resin Full Closed Double Pole

  • 36kV Outdoor VT MV Voltage Transformer Epoxy Resin Full Closed Double Pole
  • 36kV Outdoor VT MV Voltage Transformer Epoxy Resin Full Closed Double Pole
  • 36kV Outdoor VT MV Voltage Transformer Epoxy Resin Full Closed Double Pole
36kV Outdoor VT MV Voltage Transformer Epoxy Resin Full Closed Double Pole
Product Details:
Place of Origin: China
Brand Name: Shenzhen Chuangyin Co., Ltd
Certification: KEMA/type test report
Model Number: JDZW1-36
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Price: Negetiable
Packaging Details: Plywood
Delivery Time: 8days
Payment Terms: L/C, T/T
Supply Ability: 36,000.00pcs per year
Contact Now
Detailed Product Description
Insulation Type: Dry /Epoxy Cast Voltage: 36kV
Application: Outdoor Properties: Single Fase
Applied Standard: IEC 61869-1 &3 (IEC 60044-2) Rated Insulation Level: 36/70/170kV
Rated Frequency: 50/60 Hz
High Light:

medium voltage transformer

,

medium voltage potential transformer

36kV outdoor MV VT epoxy resin full-closed double-pole for measuring and protective 50/60 Hz

 

Chuangyin Voltage Transformer-JDZW1-36

 

Description:

 

Epoxy resin casting and full-closed construction, single-pole for phase to ground connection, It is widely used for measuring voltage, electric energy and protective relaying in the sing-phase or three phase power system with the frequency 50Hz or 60Hz and highest voltage for equipment 12kV

 

Basic technical data:

 

1. Installation: outdoor

2. Insulation type: dry, epoxy cast

3. Highest voltage for equipment Um (r.m.s.) 12kV

4. Rated power-frequency withstand (induced) voltage (r.m.s.): 28kV

5. Rated lightning impulse withstand voltage (peak): 75kV

5. Rated frequency: 50Hz or 60Hz

6. Applied standard: IEC 61869-1&3 (IEC 60044-2)

 

Specification:

 

 

Rated Primary Voltage

(kV)

Rated Secondary Voltage

(V)

Accuracy classes combination Rated Burden (VA) Thermal limiting Output (VA)

Rated Insulation Level

(kV)

33

34.5

35

100

110

115

120

220

240

0.2 25 500 36/70/170
0.5 50
1 100
3 200 600
5 500

 

 

 

 

 

 

 

 

 

 

 

 

 

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

 