Send Message
Home ProductsMV Voltage Transformer

Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole

Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole

  • Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole
  • Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole
  • Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole
  • Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole
Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole
Product Details:
Place of Origin: ShenZhen
Brand Name: Chuangyin
Certification: Test Report
Model Number: JDZW3-12R
Payment & Shipping Terms:
Minimum Order Quantity: 1set
Price: negotiable
Packaging Details: Carton packing for one sets, one set including three piece with Components
Delivery Time: Within 7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 36,000,00pcs per year
Contact Now
Detailed Product Description
Load Power Factor: Cos=0.8 (lagging) Secondary Voltage: 110V Or 220V
Primary Voltage: 11000V Highest Voltage: 12KV
Installation Site: Outdoor Function: Protective Relaying In Single-Phase Or Three-Phase AC Circuit
High Light:

medium voltage transformer

,

single phase voltage transformer

 

12kV Outdoor Single-Phase Epoxy Resin Type MV Voltage Transformer  With Fuse Double Pole

 

1. Introduction:

 

Voltage transformer with fully enclosed cast insulation structure, the primary and secondary windings and toroidal cores are all encapsulated in epoxy casting body for large creepage distance and improving resistance to contamination and moisture performance. It is used outdoor for measuring voltage, electric energy and protective relaying in single-phase or three-phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipment 12kV.

 

2. Technical Data:


Installation site: Outdoor
Rated frequency: 50/60Hz
Load power factor: cosΦ=0.8 (lagging)
Technical standard accords with: IEC 60044-2

IEC 61869-1&3

 

 

3. Specification:

Item Specification Unit Data
1 Um kV 12
2 Rated Insulation Level kV 12/42/75
3 Rated Primary Voltage V 11000
4 Rated Secondary Voltage V 110 or 220
 
 
Model

Rated Primary Voltage

(kV)

Rated Secondary Voltage

(kV)

Accuracy Classes combination

Rated output

(VA)

Thermal Limiting Output

(VA)

BIL

(kV)

JDZW3-12R 11 0.11 0.2 10/20 150 12/28/75
0.22 0.5 15/300 300
3 200
5M 300

Note:Other specifications can be designed as customized.

 

Outline drawing:

 

Protective Relaying Single Phase MV Voltage Transformer With Fuse Double Pole 0

 

 
 
 
 

Contact Details
Shenzhen Chuangyin Co., Ltd.

Contact Person: Mr. Dieky Lin

Tel: +86 138 2379 0397

Fax: 86-0755-8600-0614

Send your inquiry directly to us (0 / 3000)