| Place of Origin: | China | 
| Brand Name: | CY-Group | 
| Certification: | UC2, UC3,KEMA, CE, ISO, SGS, TUV, Type Test Report | 
| Model Number: | CY-JMD-09V21 | 
| Minimum Order Quantity: | 1pc | 
|---|---|
| Price: | Negotiable | 
| Packaging Details: | Plymood | 
| Delivery Time: | 3-8 days | 
| Payment Terms: | L/C, TT,D/A,D/P | 
| Supply Ability: | 3600000pcs/year | 
| Rated Voltage: | 6/9/12/24/48 | Max Switching Voltage: | 250VAC | 
|---|---|---|---|
| Max Switching Current: | 80A | Max Switching Power: | 20KVA | 
| Shock Tolerance: | 10-50Hz 1.0mm | Contact Load (resistance): | 60A 250VAC | 
| Relative Humidity: | 90% RH 40℃ | Ambient Temperature: | -40℃ To +70℃ | 
| Action Impulse Duration: | 50mS-240mS | Max Action Frequency: | 1200 Ops/h | 
| Vibration Tolerance: | 98m/s2 | ||
| Highlight: | latching power relay,permanent magnet relay | ||
Latching Relay 80A Part No. CY-JMD-09V21 for energy meter UC2, UC3 Proved/Marked
1. Part Number Description

2. Character
Meet to IEC62055-31-2005—UC2 UC3
Meet the requirements of anti-frequency magnetic field and magnetic interference in the national network.
According to RoHS requirements
Large switching power with mini body
Big strengthof magnetic latching power,anti-shock of vibration
Pulse drive,economy of power consumption and no heat rising
Permanent magnetic strength to keep stability,and save power consumption
Small contact resistance ,and little self-consumption with reliable working
3. Application
Electronic energy meter
Automatic meter reading system
Lamp controller
Complex switch
Home appliance and automatic control equipment
4. Coil Specification
| Rated voltage | Action voltage (VDC) | Max coil voltage(V) | Coil resistance x(1±10%)Ω | Rated power | 
| Single coil | ||||
| 6 | 4.8 | 12 | 36 | Single coil 1W | 
| 9 | 7.2 | 18 | 81 | |
| 12 | 9.6 | 24 | 144 | |
| 24 | 19.2 | 48 | 576 | |
| 48 | 38.4 | 96 | 2304 | 
5. Technical Specification
| Contact type | 1B(1A) | Insulation resistance | ≥1000MΩ(500VDC) | |
| Contact material | AgSoO2 | Dielectric strength | Coil--contact | ≥4000VAC 1min | 
| Contact--contact | ≥1500VAC 1min | |||
| Contact load (resistance) | 80A 250VAC | Action time | close | ≤20mS | 
| open | ≤20mS | |||
| Contact resistance (mΩ) | ≤2mΩ | Action impulse duration | 50mS-240mS | |
| Max switching voltage | 250VAC | Life (time) | Electrical life(ops) | 1x 104 (circle) | 
| Mechanical life (ops) | 1x 106 (circle) | |||
| Max switching current | 80A | Max action frequency | 1200 ops/h | |
| Max switching power | 20KVA | Vibration tolerance | 98m/s2 | |
| Short time impact current | 2500A 10ms no sinter 4500A 10ms no explosion | Shock tolerance | 10-50Hz 1.0mm | |
| Ambient temperature | -40℃ to +70℃ | Relative humidity | 90% RH 40℃ | |
6. Dimension

7.Wiring Diagram

Remarks:
The drawing does not show tolerance. It is subject to below range:
≤1mm ±0.2
1-5mm ±0.3
≥5mm ±0.4
The output terminal in above drawing is for customers’reference only. The dimension and connection way of output terminal can be customerized.
Contact Person: Mr. Dieky Lin
Tel: +86 138 2379 0397
Fax: 86-0755-8600-0614
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed
36kv Indoor Epoxy resin cast current transformer MV LRZ3-36G Chuangyin
Chuangyin 12kV MV CT Current Transformer for Air Insulation Switchgear
100A/40mA Split Core Current Transformer Open type CT CY-KCT01
Clamp On Split Core Current Transformer Open Distributed Measurement Systems
Epoxy Resin Split Core Current Transducer JDZ-17.5(24) Voltage Transformer Waterproof CT
500A 50/60Hz Open type Split Core Current Transformer Smart Logger
35kV 2# And 3# Plug In euromold termination kit Connector For PT
Epoxy Resin Cast Plug In Bushing GIS IEC 42KV 800A /1250A For Outdoor
42KV 800A /1250A Outdoor GIS Plug In Bushing IEC Epoxy Resin