Place of Origin: | China |
Brand Name: | CY-Group |
Certification: | UC2, UC3,KEMA, CE, ISO, SGS, TUV, Type Test Report |
Model Number: | . CY-JMD-12V10 |
Minimum Order Quantity: | 1pc |
---|---|
Price: | Negotiable |
Packaging Details: | Plymood |
Delivery Time: | 3-8 days |
Payment Terms: | L/C, TT,D/A,D/P |
Supply Ability: | 3600000pcs/year |
Rated Voltage: | 6/9/12/24/48 | Action Voltage (VDC): | Max.38.4 |
---|---|---|---|
Max Coil Voltage(V): | Max.96 | Shock Tolerance: | 10-50Hz 1.0mm |
Rated Power: | 12+12 Single Coil 1.5W Double Coil 3W | Short Time Impact Current: | 2500A 10ms No Sinter 4500A 10ms No Explosion |
High Light: | latching power relay,24 volt latching relay |
Latching Relay 90A Part No. CY-JMD-09V19 for energy meter UC2, UC3 Proved/Marked Competitive price
1. Part Number Description
2. Character
Meet to IEC62055-31-2005—UC2 UC3
Meet the requirements of anti-frequency magnetic field and magnetic interference in the national network.
According to RoHS requirements
Large switching power with mini body
90A contact switch
Big strengthof magnetic latching power,anti-shock of vibration
Pulse drive,economy of power consumption and no heat rising
Permanent magnetic strength to keep stability,and save power consumption
Small contact resistance ,and little self-consumption with reliable working
3. Application
Electronic energy meter
Automatic meter reading system
Lamp controller
Complex switch
Home appliance and automatic control equipment
4. Coil Specification
Rated voltage | Action voltage (VDC) | Max coil voltage(V) | Coil resistance x(1±10%)Ω | Rated power | |
Single coil | Double coil | ||||
6 | 4.8 | 12 | 16 | 8+8 |
Single coil 2.25W
Double coil 4.5W |
9 | 7.2 | 18 | 36 | 18+18 | |
12 | 9.6 | 24 | 64 | 32+32 | |
24 | 19.2 | 48 | 256 | 128+128 | |
48 | 38.4 | 96 | 1024 | 512+512 |
5. Technical Specification
Contact type | 1B(1A) | Insulation resistance | ≥1000MΩ(500VDC) | |
Contact material | AgSoO2 | Dielectric strength | Coil--contact | ≥4000VAC 1min |
Contact--contact | ≥2000VAC 1min | |||
Contact load (resistance) | 120A 250VAC | Action time | close | ≤20mS |
open | ≤20mS | |||
Contact resistance (mΩ) | ≤2mΩ | Action impulse duration | 50mS-240mS | |
Max switching voltage | 250VAC | Life (time) | Electrical life(ops) | 1x 104 (circle) |
Mechanical life (ops) | 1x 106 (circle) | |||
Max switching current | 120A | Max action frequency | 1200 ops/h | |
Max switching power | 30KVA | Vibration tolerance | 98m/s2 | |
Short time impact current |
3000A 10ms no sinter 6000A 10ms no explosion |
Shock tolerance | 10-50Hz 1.0mm | |
Ambient temperature | -40℃ to +70℃ | Relative humidity | 90% RH 40℃ |
6. Dimension
7. Wiring Diagram
Remarks:
The drawing does not show tolerance. It is subject to below range:
≤1mm ±0.2
1-5mm ±0.3
≥5mm ±0.4
The output terminal in above drawing is for customers’reference only. The dimension and connection way of output terminal can be customerized.
Contact Person: Sales Manager
Tel: +8613823790397
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed
36kv Indoor Epoxy resin cast current transformer MV LRZ3-36G Chuangyin
Chuangyin 12kV MV CT Current Transformer for Air Insulation Switchgear
100A/40mA Split Core Current Transformer Open type CT CY-KCT01
Clamp On Split Core Current Transformer Open Distributed Measurement Systems
Epoxy Resin Split Core Current Transducer JDZ-17.5(24) Voltage Transformer Waterproof CT
500A 50/60Hz Open type Split Core Current Transformer Smart Logger
35kV 2# And 3# Plug In euromold termination kit Connector For PT
Epoxy Resin Cast Plug In Bushing GIS IEC 42KV 800A /1250A For Outdoor
42KV 800A /1250A Outdoor GIS Plug In Bushing IEC Epoxy Resin